Class CCANBusReader

Inheritance Relationships

Base Types

Class Documentation

class CCANBusReader : public mrpt::system::COutputLogger, public mrpt::hwdrivers::CGenericSensor

This “software driver” implements the communication protocol for interfacing a SICK LMS 2XX laser scanners through a standard RS232 serial port (or a USB2SERIAL converter). The serial port is opened upon the first call to “doProcess” or “initialize”, so you must call “loadConfig” before this, or manually call “setSerialPort”. Another alternative is to call the base class method C2DRangeFinderAbstract::bindIO, but the “setSerialPort” interface is probably much simpler to use.

For an example of usage see the example in “samples/SICK_laser_serial_test”. See also the example configuration file for rawlog-grabber in “share/mrpt/config_files/rawlog-grabber”.

 PARAMETERS IN THE ".INI"-LIKE CONFIGURATION STRINGS:
-------------------------------------------------------
  [supplied_section_name]
  COM_port_WIN = COM1   // Serial port to connect to
  COM_port_LIN = ttyS0

  COM_baudRate = 38400 // Possible values: 9600 (default), 38400, 5000000
  mm_mode      = 1/0   // 1: millimeter mode, 0:centimeter mode (Default=0)
  FOV          = 180   // Field of view: 100 or 180 degrees (Default=180)
  resolution   =  50   // Scanning resolution, in units of 1/100 degree.
Valid values: 25,50,100 (Default=50)


  pose_x=0.21   // Laser range scaner 3D position in the robot (meters)
  pose_y=0
  pose_z=0.34
  pose_yaw=0    // Angles in degrees
  pose_pitch=0
  pose_roll=0

Public Functions

CCANBusReader()

Constructor

~CCANBusReader() override

Destructor

inline void setSerialPort(const std::string &port)

Changes the serial port to connect to (call prior to ‘doProcess’), for example “COM1” or “ttyS0”. This is not needed if the configuration is loaded with “loadConfig”.

inline std::string getSerialPort() const

See also

setSerialPort

inline void setBaudRate(int baud)

Changes the serial port baud rate (call prior to ‘doProcess’); valid values are 9600,38400 and 500000. This is not needed if the configuration is loaded with “loadConfig”.

See also

getBaudRate

inline int getBaudRate() const

See also

setBaudRate

inline void setCANReaderTimeStamping(bool setTimestamp = false)

Enables/Disables the addition of a timestamp according to the arrival time to the converter (default=false) (call prior to ‘doProcess’) This is not needed if the configuration is loaded with “loadConfig”.

inline bool getCANReaderTimeStamping()
inline void setCANReaderSpeed(const unsigned int speed)

Sets the CAN reader speed when connecting to the CAN Bus

inline unsigned int getCANReaderSpeed()
inline unsigned int getCurrentConnectTry() const

If performing several tries in ::initialize(), this is the current try loop number.

void doProcessSimple(bool &outThereIsObservation, mrpt::obs::CObservationCANBusJ1939 &outObservation, bool &hardwareError)

Specific laser scanner “software drivers” must process here new data from the I/O stream, and, if a whole scan has arrived, return it. This method will be typically called in a different thread than other methods, and will be called in a timely fashion.

virtual void initialize() override

Set-up communication with the laser. Called automatically by rawlog-grabber. If used manually, call after “loadConfig” and before “doProcess”.

In this class this method does nothing, since the communications are setup at the first try from “doProcess” or “doProcessSimple”.

virtual void doProcess() override

This method will be invoked at a minimum rate of “process_rate” (Hz)

Throws:

This – method must throw an exception with a descriptive message if some critical error is found.

Protected Functions

virtual void loadConfig_sensorSpecific(const mrpt::config::CConfigFileBase &configSource, const std::string &iniSection) override

See the class documentation at the top for expected parameters