Public Attributes | List of all members
SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag Struct Reference

A structure for aggregating the data that collectively define the signal config and status. More...

#include <SickLMS2xx.hh>

Public Attributes

uint16_t sick_angle_of_measurement
 Angles used to reference target for power measurement. More...
 
uint16_t sick_current_angle
 Angle used for power measurement. More...
 
uint16_t sick_peak_threshold
 Peak threshold in ADC incs for power measurement. More...
 
uint16_t sick_peak_threshold_actual_value
 Actual value of the peak threshold in ADC incs. More...
 
uint16_t sick_peak_threshold_target_value
 Target value of the peak threshold in ADC incs. More...
 
uint16_t sick_reference_scale_1_dark_100
 Receive signal amplitude in ADC incs when reference signal is switched off (Signal 1, Dark 100%) More...
 
uint16_t sick_reference_scale_1_dark_66
 Receive signal amplitude in ADC incs when reference signal is switched off (Signal 1, Dark 66%) More...
 
uint16_t sick_reference_scale_2_dark_100
 Receive signal amplitude in ADC incs when reference signal is switched off (Signal 2, Dark 100%) More...
 
uint16_t sick_reference_scale_2_dark_66
 Receive signal amplitude in ADC incs when reference signal is switched off (Signal 2, Dark 66%) More...
 
uint16_t sick_reference_target_mean_measured_vals
 Reference target "mean measured values." Low byte: Current number of filtered mean measured values. High byte: Max num filtered mean measured value since power-on. More...
 
uint16_t sick_reference_target_single_measured_vals
 Reference target "single measured values." Low byte: Current number of filtered single measured values. High byte: Max num filtered single measured value since power-on. More...
 
uint16_t sick_signal_amplitude
 Laser power in % of calibration value. More...
 
uint16_t sick_signal_amplitude_calibration_val
 Calibration of the laser power. More...
 
uint16_t sick_stop_threshold_actual_value
 Actual value of the stop threshold in ADC incs. More...
 
uint16_t sick_stop_threshold_target_value
 Target value of the stop threshold in ADC incs. More...
 

Detailed Description

A structure for aggregating the data that collectively define the signal config and status.

Definition at line 313 of file SickLMS2xx.hh.

Member Data Documentation

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_angle_of_measurement

Angles used to reference target for power measurement.

Definition at line 321 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_current_angle

Angle used for power measurement.

Definition at line 319 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_peak_threshold

Peak threshold in ADC incs for power measurement.

Definition at line 320 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_peak_threshold_actual_value

Actual value of the peak threshold in ADC incs.

Definition at line 326 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_peak_threshold_target_value

Target value of the peak threshold in ADC incs.

Definition at line 324 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_scale_1_dark_100

Receive signal amplitude in ADC incs when reference signal is switched off (Signal 1, Dark 100%)

Definition at line 314 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_scale_1_dark_66

Receive signal amplitude in ADC incs when reference signal is switched off (Signal 1, Dark 66%)

Definition at line 316 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_scale_2_dark_100

Receive signal amplitude in ADC incs when reference signal is switched off (Signal 2, Dark 100%)

Definition at line 315 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_scale_2_dark_66

Receive signal amplitude in ADC incs when reference signal is switched off (Signal 2, Dark 66%)

Definition at line 317 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_target_mean_measured_vals

Reference target "mean measured values." Low byte: Current number of filtered mean measured values. High byte: Max num filtered mean measured value since power-on.

Definition at line 328 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_reference_target_single_measured_vals

Reference target "single measured values." Low byte: Current number of filtered single measured values. High byte: Max num filtered single measured value since power-on.

Definition at line 327 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_signal_amplitude

Laser power in % of calibration value.

Definition at line 318 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_signal_amplitude_calibration_val

Calibration of the laser power.

Definition at line 322 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_stop_threshold_actual_value

Actual value of the stop threshold in ADC incs.

Definition at line 325 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_signal_status_tag::sick_stop_threshold_target_value

Target value of the stop threshold in ADC incs.

Definition at line 323 of file SickLMS2xx.hh.


The documentation for this struct was generated from the following file:


sicktoolbox
Author(s): Jason Derenick , Thomas Miller
autogenerated on Tue Sep 10 2019 03:37:35