Public Attributes | List of all members
SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag Struct Reference

A structure for aggregating the data that define a scan profile obtained from reply B0 (See page 49 Telegram listing) More...

#include <SickLMS2xx.hh>

Public Attributes

uint8_t sick_field_a_values [SICK_MAX_NUM_MEASUREMENTS]
 Reflects the Field A bit value returned w/ range measurement. More...
 
uint8_t sick_field_b_values [SICK_MAX_NUM_MEASUREMENTS]
 Reflects the Field B but value returned w/ range measurement. More...
 
uint8_t sick_field_c_values [SICK_MAX_NUM_MEASUREMENTS]
 Reflects the Field C (or dazzle - depending upon sensor mode) value returned w/ range measurement. More...
 
uint16_t sick_measurements [SICK_MAX_NUM_MEASUREMENTS]
 Range/reflectivity measurement buffer. More...
 
uint16_t sick_num_measurements
 Number of measurements. More...
 
uint8_t sick_partial_scan_index
 Indicates the start angle of the scan (This is useful for partial scans) More...
 
uint8_t sick_real_time_scan_index
 If real-time scan indices are requested, this value is set (modulo 256) More...
 
uint8_t sick_telegram_index
 Telegram index modulo 256. More...
 

Detailed Description

A structure for aggregating the data that define a scan profile obtained from reply B0 (See page 49 Telegram listing)

Definition at line 414 of file SickLMS2xx.hh.

Member Data Documentation

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_a_values[SICK_MAX_NUM_MEASUREMENTS]

Reflects the Field A bit value returned w/ range measurement.

Definition at line 417 of file SickLMS2xx.hh.

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_b_values[SICK_MAX_NUM_MEASUREMENTS]

Reflects the Field B but value returned w/ range measurement.

Definition at line 418 of file SickLMS2xx.hh.

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_c_values[SICK_MAX_NUM_MEASUREMENTS]

Reflects the Field C (or dazzle - depending upon sensor mode) value returned w/ range measurement.

Definition at line 419 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_measurements[SICK_MAX_NUM_MEASUREMENTS]

Range/reflectivity measurement buffer.

Definition at line 416 of file SickLMS2xx.hh.

uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_num_measurements

Number of measurements.

Definition at line 415 of file SickLMS2xx.hh.

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_partial_scan_index

Indicates the start angle of the scan (This is useful for partial scans)

Definition at line 422 of file SickLMS2xx.hh.

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_real_time_scan_index

If real-time scan indices are requested, this value is set (modulo 256)

Definition at line 421 of file SickLMS2xx.hh.

uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_telegram_index

Telegram index modulo 256.

Definition at line 420 of file SickLMS2xx.hh.


The documentation for this struct was generated from the following file:


sicktoolbox
Author(s): Jason Derenick , Thomas Miller
autogenerated on Tue Sep 10 2019 03:37:35