A structure for aggregating the data that define a scan profile obtained from reply B0 (See page 49 Telegram listing) More...
#include <SickLMS2xx.hh>
Public Attributes | |
uint8_t | sick_field_a_values [SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field A bit value returned w/ range measurement. More... | |
uint8_t | sick_field_b_values [SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field B but value returned w/ range measurement. More... | |
uint8_t | sick_field_c_values [SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field C (or dazzle - depending upon sensor mode) value returned w/ range measurement. More... | |
uint16_t | sick_measurements [SICK_MAX_NUM_MEASUREMENTS] |
Range/reflectivity measurement buffer. More... | |
uint16_t | sick_num_measurements |
Number of measurements. More... | |
uint8_t | sick_partial_scan_index |
Indicates the start angle of the scan (This is useful for partial scans) More... | |
uint8_t | sick_real_time_scan_index |
If real-time scan indices are requested, this value is set (modulo 256) More... | |
uint8_t | sick_telegram_index |
Telegram index modulo 256. More... | |
A structure for aggregating the data that define a scan profile obtained from reply B0 (See page 49 Telegram listing)
Definition at line 414 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_a_values[SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field A bit value returned w/ range measurement.
Definition at line 417 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_b_values[SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field B but value returned w/ range measurement.
Definition at line 418 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_field_c_values[SICK_MAX_NUM_MEASUREMENTS] |
Reflects the Field C (or dazzle - depending upon sensor mode) value returned w/ range measurement.
Definition at line 419 of file SickLMS2xx.hh.
uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_measurements[SICK_MAX_NUM_MEASUREMENTS] |
Range/reflectivity measurement buffer.
Definition at line 416 of file SickLMS2xx.hh.
uint16_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_num_measurements |
Number of measurements.
Definition at line 415 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_partial_scan_index |
Indicates the start angle of the scan (This is useful for partial scans)
Definition at line 422 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_real_time_scan_index |
If real-time scan indices are requested, this value is set (modulo 256)
Definition at line 421 of file SickLMS2xx.hh.
uint8_t SickToolbox::SickLMS2xx::sick_lms_2xx_scan_profile_b0_tag::sick_telegram_index |
Telegram index modulo 256.
Definition at line 420 of file SickLMS2xx.hh.