File: ublox_msgs/CfgRATE.msg
Raw Message Definition
# CFG-RATE (0x06 0x08)
# Navigation/Measurement Rate Settings
#
# This message allows the user to alter the rate at which navigation solutions
# (and the measurements that they depend on) are generated by the receiver. The
# calculation of the navigation solution will always be aligned to the top of a
# second zero (first second of the week) of the configured reference time
# system. For protocol version 18 and later the navigation period is an integer
# multiple of the measurement period.
# - Each measurement triggers the measurements generation and raw data output.
# - The navRate value defines that every nth measurement triggers a navigation
# epoch.
# - The update rate has a direct influence on the power consumption. The more
# fixes that are required, the more CPU power and communication resources
# are required.
# - For most applications a 1 Hz update rate would be sufficient.
# - When using Power Save Mode, measurement and navigation rate can differ from
# the values configured here
uint8 CLASS_ID = 6
uint8 MESSAGE_ID = 8
uint16 measRate # Measurement Rate, GPS measurements are
# taken every measRate milliseconds [ms]
uint16 navRate # Navigation Rate, in number of measurement
# cycles. On u-blox 5 and u-blox 6, this parameter
# cannot be changed, and always equals 1.
uint16 timeRef # The time system to which measurements are aligned
uint16 TIME_REF_UTC = 0
uint16 TIME_REF_GPS = 1
uint16 TIME_REF_GLONASS = 2 # not supported in protocol versions less than 18
uint16 TIME_REF_BEIDOU = 3 # not supported in protocol versions less than 18
uint16 TIME_REF_GALILEO = 4 # not supported in protocol versions less than 18
Compact Message Definition
uint8 CLASS_ID=6
uint8 MESSAGE_ID=8
uint16 TIME_REF_UTC=0
uint16 TIME_REF_GPS=1
uint16 TIME_REF_GLONASS=2
uint16 TIME_REF_BEIDOU=3
uint16 TIME_REF_GALILEO=4
uint16 measRate
uint16 navRate
uint16 timeRef